Ardex AF195 High Temperature LVT Adhesive
$27.73
$43.81
Description ARDEX AF195 High Temperature LVT Adhesive is a fibre reinforced, water-based, low odour, solvent free, acrylic, emulsion-based floorcovering adhesive. ARDEX AF195 High Temperature LVT Adhesive has very good early and long-term adhesive strength and is protected from biodegradation. ARDEX AF195 High Temperature LVT Adhesive meets the requirement guidelines for the EMICODE licence ‘EC1 PLUS’, achieving the lowest possible emission limits. ARDEX AF195 High Temperature LVT Adhesive is ideal for installing all types of vinyl floorcoverings, rubber (up to 4mm in thickness) and linoleum in interior dry locations. It is suitable for use in areas of high solar gain such as conservatories and areas where floor to ceiling windows are installed. Priming: Priming is not required, however, on highly absorbent surfaces it can be advantageous to prime with ARDEX P 51 Priming and Bonding Agent diluted 1:3 with cold, clean water. This will maintain the working time and ensure maximum coverage of the adhesive. Substrate preparation: The subfloor must contain an effective damp proof membrane and be dry, with an equilibrium relative humidity of 75% or below. Where an effective damp proof membrane is absent, or the relative humidity of the subfloor is above 75% RH, consult the ARDEX Moisture Control brochure or contact ARDEX Technical Services for the correct product selection. The subfloor must be hard, clean, free from barrier materials, sound and smooth in accordance with the relevant clauses of BS 8203 and BS 8204. Any dust should be removed using suitable vacuum equipment, prior to applying ARDEX AF195 High Temperature LVT Adhesive, as it can affect both the coverage and performance of the adhesive. Uneven and non-absorbent subfloors should be levelled with the appropriate ARDEX Latex or Water-Based Levelling and Smoothing Compound e.g. ARDITEX NA® or ARDEX K 40 FLOW. ARDEX ARDURAPID A 45 Rapid Drying and Hardening Internal Repair Mortar can be used for repairs to the subfloor/stairs etc. up to 50mm thick, in accordance with the product datasheet. Joints, nail holes and imperfections in plywood, or minor surface damage to existing levelling and smoothing compounds i.e. footprints or trowel marks, may be pre-smoothed and levelled prior to the application of ARDEX AF195 High Temperature LVT Adhesive, using ARDEX FEATHER FINISH in accordance with the product datasheet. Fabricated underlays such as flooring grade plywood (SP101) should be installed where required over existing timber bases. Wood-based fabricated underlays should be suitable for the floorcovering and be at the equilibrium moisture content they will have in service at the time they are covered. Mixing: ARDEX AF195 High Temperature LVT Adhesive is ready for use, but for optimum performance the adhesive should be thoroughly mixed to ensure the even dispersion of polymers before application. Application: The installation area and subfloor should be kept at the appropriate temperature as specified by the floorcovering manufacturer and the relevant clauses of BS 8203. These temperatures need to be maintained 48 hours prior to installation, during installation, and 48 hours after installation. ARDEX AF195 High Temperature LVT Adhesive should be applied evenly to the suitably prepared substrate using the appropriate serrated trowel, held approximately at a 60-degree angle to the subfloor to maximise coverage and avoid forming pools of adhesive. Allowing the adhesive to air will help to reduce lateral slide and adhesive squeeze when installing floorcoverings. Floorcoverings can be applied directly into the semi-wet adhesive on absorbent backgrounds after the airing time, between 5-15 minutes depending on ambient conditions. Periodically check that the adhesive has transferred to the rear of the floorcovering. Stop work if the adhesive no longer transfers to the rear of the floorcovering. Remove any adhesive that is not covered, and clean the surface of the subfloor. Remove all traces of adhesive. Remove any air pockets with a cork board or rubbing tool whilst the adhesive is still wet and roll the flooring with a 68kg roller as above. Rolling the floorcovering when the ARDEX AF195 adhesive is wet will flatten the serrations and minimise the potential for these to mirror through thin resilient floorings when the adhesive dries. Some floorcoverings may benefit from further rolling/smoothing, usually after 1 hour. Heat welding should only commence once the adhesive has dried sufficiently. Do not allow the floor to be wet cleaned immediately after the floorcovering has been installed. Allow significant time for the ARDEX AF195 adhesive bond to develop before wet cleaning commences, typically 48 hours at 20°C. When applying adhesive onto the substrate, ensure that any adhesive which is surplus to requirements, and has been moved across the subfloor, is not placed back into the container. It should be placed into an alternative container for safe, easy disposal. This will avoid possible contamination issues. Underfloor heating: Underfloor heating systems should be commissioned in accordance with the heating manufacturer’s instructions; if comment cannot be found then the guidance given in BS 8203 and BS 8204 should be followed. Thermal cycling of the subfloor will require raising the temperature of the substrate slowly, usually 5°C a day, to full operating temperature, held for a defined period, and slowly brought back down, usually 5°C a day, so that any shrinkage that is likely to take place occurs before the floorcovering is installed. If moisture tests are required to verify the relative humidity of the substrate, the underfloor heating system should be switched off for 48 hours prior to testing. If moisture testing is not required, or after the tests are completed, the heating system should be stabilised to room temperature, but not below 15°C, before installing the floorcovering. The surface of the substrate can then be repaired/smoothed with the appropriate ARDEX product and allowed to dry. The floorcovering should be allowed to acclimatise to the substrate temperature before installation with ARDEX AF195 High Temperature LVT Adhesive. After installation allow at least 48 hours of constant temperature for the adhesive to properly cure, before slowly increasing the temperature up to the normal operating temperature of the area. Do not subject the floor to static or dynamic loads, loaded trolleys, etc., or move fixtures, furniture, etc., onto the flooring until the ARDEX AF195 adhesive has fully set, typically 48 hours at 20°C. Heavy duty areas: ARDEX AF195 High Temperature LVT Adhesive is suitable for use over underfloor heating systems and is classified as high temperature resistant up to 50°C. The surface floor temperature must not exceed the max. allowed temperature according to the floorcovering manufacturer. Consult the floorcovering manufacturer for guidance. Where extreme heat is present, e.g. from a log burner, use ARDEX AF 2575 PLUS 1K or ARDEX AF 2525 Heavy Duty Adhesive. Technical Data: Airing Time: The time the adhesive must be left to air before applying the floorcovering. 5-15 minutes* Working Time: The time in which the adhesive can receive the floorcovering, after the initial airing time. Up to 30 minutes* Open Time: The combination of airing and working time. Up to 35 minutes* Click here to view this product on the manufacturers website. Product Datasheet
Soft Flooring Adhesives